-40%

Pro Audio Signal Distortion Device Test Equipment Analyzer Tester Meter TDM-1911

$ 114.16

Availability: 100 in stock
  • UPC: Does not apply
  • Condition: New
  • Brand: Unbranded
  • MPN: Does Not Apply
  • Return shipping will be paid by: Buyer
  • Model: TDM-1911
  • Voltage: 110V/220V
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Restocking Fee: No
  • Item must be returned within: 60 Days
  • All returns accepted: Returns Accepted

    Description

    Maxmox
    Best Customer Service
    New Deals Everyday
    100% Money Back Guarantee
    Easy & Secure Payments
    Pro Audio Signal Distortion Device Test Equipment Analyzer Tester Meter TDM-1911
    Description:
    TMD-1911 series automatic distortion tester to measure 400Hz or 1000Hz signal is small to 0.01% of distortion, while 20Hz AC signal relative to the level of 100KHz was measured as a measure of distortion, can be performed, such as radios, modulation check tape recorders and other audio products, the level of distortion and simultaneously two meter display, the distortion measure fundamental frequency suppression circuit having a wide range of the filter, measurements.
    Feature:
    1. Level and distortion together display with two ports accurately.
    2. Lightweight, easy operation.
    3. With wide range filter, can test accurately even impurities in signal.
    Specification:
    Model Name: TDM-1911 Distortion Meter
    Voltage: 220V/110V±10%  50/60Hz
    Distortion measurement:
    1. The input level: 10 m V to 100 VRMS
    2. The measurement frequency :400 Hz and 1 KHZ frequency of two points
    3. The measuring range :0.1 to 30% of six kinds of full scale
    4. The harmonic accuracy :+ / - 0.5 dB (f0 2 to 10 kz)
    5. The residual distortion : greater than or equal to 70 db (distortion than less than or equal to 10 db, input level greater than or equal to 30 mv)
    6. The fundamental frequency suppression is greater than or equal to 60 db (f0 + / - 5%)
    7. Full scale accuracy :+ / - 3% (20 db)
    8. Automatic frequency selection :can measure the rotation frequency of the nominal distortion degree of plus or minus 5%
    Level measurement:
    1. The measuring range: 100 mv, a total of seven to 100 v range
    2. The frequency response (1 KHZ)
    + / - 0.5 dB or less (from 20 hz to 50 KHZ)
    1 mm or less db (from 20 hz to 100 KHZ)
    3.Accuracy: + / - 3% or less full scale (1 KHZ)
    4. Input impedance: 100 k Ω
    5. The AC output voltage: about 1 VRMS (the level range)
    6. Enter 100 largest VRMS (DC + AC)
    7. The power supply requirements: 110 v / 220 v, 50/60 hz, 12 va
    8. The contour size: 283 (L) * 155 (H) * 264 (D) mm3
    9. Weight: about 5 kg
    10. Attachment
    User manual *1
    0.2 A tube*2
    The power line*1
    BNC cable * 1
    The matters needing attention before use:
    1. The maximum allowable at the input AC input voltage of 200 v.Beyond this range attenuation board may be damaged.
    2. The use of
    TDM - 191 distortion meter in 5-350 - c temperature range, avoid using instruments in this temperature range.
    3. Before use distortion meter for measuring, please make sure that the distortion meter pointer is set on the dial "0".If the pointer is not zero, but by adjusting the knob of the front panel
    Summary:
    TDM - 1911 can be used to measure the distortion degree of audio products and the level parameters.Measured 400 hz & 1 KHZ frequency of two point signal distortion degree of 0.1% to 30% six kinds of full scale.Through three light input level under calibration Settings can know distortion measurement working condition.
    With a wide range of filter can be measured, including shake sway and flutter signal distortion measurement.Can automatically distinguish between 400 hz and 1 KHZ frequency point and two, respectively, with green and yellow light instructions, said red indicator measuring the frequency of the signal does not fall within the scope of measurement.
    In the distortion degree of the input signal level measurement, the distortion measurement can eliminate the need to adjust the level meter deviation.
    When measuring the simply select correct range on the front panel, and then press the button, automatically measuring instrument.
    Panel display:
    Level meter: in "Volt" and "dBm" shows that the reading of the input signal level
    2. Filter: yellow indicator according to input signal frequency is 400 hz, green light input signal frequency of 1 KHZ, said red lights input signal frequency measurement range
    3. The distortion degree of tables: in "%" and "dB" display input signal distortion degree of the readings
    4. Level: set the knob before measuring adjustment knob to zero level pointer
    5. Distortion setting knob: before measuring distortion degree adjustment knob that pointer to zero
    6. Level range knob: through correctly in the seven key choice range of level measurement range
    7. Input terminals: measuring signal input terminal
    8. Distortion range knob: through six key choice range of distortion degree of the correct measuring range
    9. The power switch
    The fuse holder: insert the appropriate insurance tube to avoid choosing a wrong input voltage burning equipment
    11. Ac socket
    12. The range of terminal: monitor output terminal.When the input frequency is 400 hz or 1 KHZ, basic frequency are filtered out, the frequency of the signal in other to enter the terminal.Output level affect the level meter (1) of the readings.When the distortion degree level meter with tables are full scale, can produce the output level of about 1 VRMS.Distortion degree if the table is full scale range and level meter is lower than the full scale range, output level is less than 1 v.
    13. The voltage selector: mainly supply operation to choose the appropriate input voltage.
    Distortion measurement:
    1, ensure that the input signal level in the range of the instrument allowed range
    Two or three filter light distortion measurement condition.Yellow lights said measuring frequency is 400 hz, green lights said measuring the frequency of 1 KHZ, red lights the measured signal frequency unpredictable.
    3, this instrument is automatic measurement only input frequency is 400 hz distortion degree of plus or minus 5% or 1 KHZ plus or minus 5%.If the input signal is not accurate 400 hz or 1 KHZ, for example in 400 hz or 1 KHZ range of plus or minus 5%, its fundamental frequency rejection ratio will be between 0.05% and 0.03% (66 db and 70 db) can be observed through the figure 3 base frequency suppression ratio curve.So the frequency of the input signal is the closer it gets to the fixed frequency filter, get the more accurate readings.
    4, this automatic distortion meter don't need to do any choice can be automatically measured 400 hz or distortion degree of 1 KHZ.
    5, and start measuring
    (before the measurement, please make sure that the pointer to the header (1) and (3) to zero, or set up (4) and (5) adjust pointer to zero) will instrument electricity, to ensure that the voltage selector in the right gear (110 v or 220 v, press the power switch pet-name ruby, "No Go" aligned with the said instrument is available.
    Press the 6 key as input signals to choose the appropriate range.30% at the end press keys, through all landowners to distortion meter input signal.
    If the input signal is 400 hz, the yellow indicator, if the input signal is 1 KHZ, the green light is lit.
    Red indicator according to the input signal is too high or too low, range outside the scope of the level meter.Outside the outer filter or frequency.As shown in figure 5 level Pointers, to measure the distortion degree.
    When the yellow or green light, measurement results through the header (3) can be read.Of course, choosing the appropriate range measurement can get more accurate results.
    Fifth, level measurement:
    1. Choose an appropriate input level range
    2. Input signal at 7, if the input signal frequency range within 10 hz - 100 KHZ, header (1) to measure the level of value is displayed "VOLTS or dB"
    Payment:
    We currently only accept payment through PayPal.
    Payment must be made within 12 days after the auction/bid ends, or eBay will open Unpaid Item case automatically later.
    Feedback:
    We strive for positive Feedback on all transactions and nothing less than an overall Detail Seller Rating (DSR) of 5 STAR.If you are considering giving a neutral or negative Feedback or a low DSR. Do write to us and give us an opportunity to address your concerns firstly.We will leave the positive feedback when we got your positive feedback.
    Delivery details:
    We are not responsible for undeliverable address. We reserve the right to charge the shipping fee again for returned items due to wrong address.
    Items are generally shipped out the 1-5 business day after your payment has been cleared (Sat. & Sun. excluded.)
    Orders from the United States will all be shipped out via epacket. The shipment usually takes 10-14 days, if you need the item urgently, please contact us for detail before purchase.
    Customers from other country, if your order passed 30 USD , your package with be shipped with tracking service for free ,if less than 30 USD, your order will be shipped without tracking number by China Post. The shipment usually takes 20-30 days.if you need the item urgently, please contact us for detail before purchase
    RETURN POLICY:
    We offer 14 days return policy from the day you received your item under the following conditions All returns must be in the original non-damaged condition, including packaging, documentation, warranty cards, manuals and accessories or else it will not be accepted.
    Original shipping & handling charges are not refundable.
    Customer is responsible for shipping, shipping cost and proof of delivery on all returns. Please be sure that you return shipments are properly packed and fully insured. We are not responsible for returned packages if lost by shipper/carrier or got damaged buy carrier.
    Shipping cost (to and from buyer) will be charged for any refused shipping delivery (include duties, taxes and customs fee if any).
    TAX&VAT
    Please read this before buying International Shipping may Be Delayed Due to Customs. Customers are Responsible For All Import Charges, Tariffs, Duties, Taxes, and Fees Associated with Import of the product. Shipping Charges does not include any Import Charges, Tariffs, Duties, Taxes, and Fees Associated with it.
    Contact us:
    Please contact us with any comments, questions or suggestions that you may have bysending ebay message, All the mail will be replied within 24 hours. Please ensure your mail box would not blocked / filtered our mails.we will be happy to assist you. please feel free to contact us for WHOLESALES deal,we will surely give you a satisfatory price. We would try our best to serve you with any question / problem. Please contact us first before leaving Negative / Neutral Feedback or open any cases.
    Copyright 2018 Maxmox. All rights reserved.